U.V.
Disinfection System
Purpose: The
purpose of the UV disinfection system is to reduce the number of viable
pathogenic organisms in the plant effluent.
Description: The
UV disinfection system includes two banks of UV lamp modules arranged
in series in a concrete channel. The disinfection channel is located
in the northeast comer of the Operations
Building following Post Aeration and
immediately before discharge. Each bank contains six lamp modules with
eight lamps per module. The lamps are arranged horizontally and parallel
to the flow through the channel. The modules hang suspended into the
channel, supported by stainless steel racks that provide for the addition
of up to three additional lamp modules per bank for future expansion.
Space is also provided in the channel for installation of a third bank
of up to nine lamp modules also for future expansion. The two banks
of lamps are also provided with removable stainless steel baffles to
reduce the width of the channel as required to maintain the operating
depth and velocity necessary for effective disinfection. The baffles
will be removed when additional lamp modules are installed to meet
future flow requirements. The depth of flow in the disinfection channel
is critical to proper operation and performance of the UV disinfection
process. The required depth is maintained to within one-inch (±1/2
inch) by an automatic level controller consisting of a counterbalanced
vertically mounted swinging gate. The gate in direct response to variations
in flow swinging open further as flow increases and closing down as
flow decreases to maintain a nearly constant depth in the channel. |